The SU20KRTHWTFASSM 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 16U rack/tower configuration pre-assembled into a Tripp Lite 25U rack enclosure. This system delivers complete N+1 redundancy when used at loads up to 50%, and non-redundant operation at loads between 50 and 100%. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
Pre-assembled 16U configuration built into a 25U rack enclosure
Tripp Lite SU20KRTHWTFASSM 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in a 16U total rack/tower configuration (max output de-rates to 18kVA / 16kW when operated at 208V nominal input voltage)
Pre-built into a 25U SmartRack enclosure with 6U of open rack space able to accommodate two optional additional BP240V10RT3U external battery packs
Offers enhanced fault-tolerance and reliability with N+1 configuration support and hot-swappable whole UPS replacement options
Unique configuration ties input, output and data connections of two standard 10kVA UPS systems via detachable parallel PDU to offer 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 50% and lower
Included Parallel PDU with manual bypass switching enables hot-swappable replacement of either power module at any supported load level, with no interruption to connected equipment
Hardwire input and output connections
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Maintains full-time sine wave output within 2% of 240/120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V
Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH external battery packs
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs
Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
Rack / tower configuration installs in 16 total rack spaces (16U)
PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted
Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Pre-installed SNMPWEBCARD (one per 10kVA power module) offers communications and control via secure remote web and network interfaces
Supports Emergency Power Off (EPO) via built-in interface
Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection, frequency conversion and other operational parameters
LED / LCD display panel rotates for viewing in rackmount or tower configurations
Network-grade AC surge and noise suppression
Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions
External battery packs are field replaceable and hot swappable
$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Package Includes:
Two SU10000RT3UPM UPS power modules
Two BP240V10RT3U battery packs
One SU20KXFMRT4U 120V transformer
SUPDMB20KHW parallel PDU with Bypass switch
Pre-installed in a Tripp Lite 25U rack enclosure
PowerAlert software and complete cabling
Rackmountable - Yes
ROHS Compliant - Yes
Warranty - Yes
Spec Sheet available - Yes
Operating Temperature (Maximum):
104 F
Operating Temperature (Minimum):
32 F
Estimated Runtime:
4.30 minutes
Estimated Runtime:
0.07 hours
Rack Units (Height):
14
Warranty (Length/Type):
2-year Limited
Certifications:
Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI), IEC 61000-4-5 1995 B Surge Immunity
Depth:
25.82 in
Height:
5.14 in
Shipping Depth (with packaging):
45 in
Shipping Height (with packaging):
53 in
Shipping Width (with packaging):
27 in
Width:
17.50 in
Product Weight:
44.10 lbs
Shipping Weight:
918 lbs
Power Factor:
0.90 %
AC Voltage:
240 Volts
Active Power:
18000 Watt
DC Voltage:
240 Volts
Noise:
60 dBA
WEXT1W