The RS-232 connector is DB9F; the RS-485 connector is RJ-45; other connectors are available (see Related Items).
Built-in silicon avalanche diode surge protection against data loss and equipment damage from transient surges.
You can also "fine tune" impedance and "echo" characteristics for your individual application.
For configuration, the converter features two internal 4-position DIP switches.
Transmit data up to 115 kbps or at distances up to 4000 ft.
Operates in point to point or multipoint applications
Operates 2-wire half-duplex or 4-wire half- or full-duplex.
async (data leads) only.
Up to 32 RS485 devices can be attached to create a large multi-drop network
The RS485 driver is automatically enabled during each spacing state on the RS232 side.
Converter Signal Types - Computer
Converter Type - Other
Warranty - Yes
Spec Sheet available - Yes
Operating Temperature (Maximum):
122 F
Operating Temperature (Minimum):
32 F
Certifications:
CE
Input Signal Types:
RS-232
Output (Converted) Signal Type:
RS-485
Regulatory Compliance:
TAA
Warranty (Length/Type):
1 Year
Cable Required:
Unconditioned twisted pair between converters: 2 or 4 wires (1 or 2 pairs)
Data Format:
Transparent
Distance (Maximum):
Between RS-232 device and converter: 50 ft. (15.2 m), but converters not directly attached will be underpowered
Between non-RS-232 device and converter: 9 mi. (14.4 km)
Enclosure:
ABS plastic
Environmental Operation:
Humidity: 5 to 95% non-condensing
Hardware Flow Control Signaling:
Raise DSR in response to DTR; raise CD in response to carrier; raise CTS in response to RTS (after no delay or 8-ms delay, user-selectable); carrier is either constantly on or controlled by RTS, user-selectable
Operation:
Transparent to 2-wire half-duplex or 4-wire full- or half-duplex
Protocol:
Asynchronous
Software Flow Control:
Transparent
Speed (Maximum):
Transparent to 115.2 kbps
Surge Protection:
Internal Silicon Avalanche Diodes dissipate surges up to 600 watts per wire within 1 ms
User Controls:
(2) internal 4-position DIP switches for configuration
Interface:
To devices: RS-232: Pinned according to TIA-574 on DB9, DCE;